Pach-and-company AeGIS 4000_4000RT Manual Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires de communication Pach-and-company AeGIS 4000_4000RT Manual. Pach and Company AeGIS 4000_4000RT Manual User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - AeGIS 4000

AeGIS 4000Installation and Programming ManualPACH & COMPANY 941 Calle Negocio Phone: 1-888-678-7224www.pach-co.com San Clemente, CA 92673 Fa

Page 2

Pach and Company warrants the wiegand card, clam, and keyfob to be free of defects in material or workmanship for a period of three (3) months from th

Page 3

4. Under no circumstances will Pach and Company honor warranty any product found to have been altered,repaired, and/or modified by the end-user consum

Page 4 - TABLE OF CONTENTS

9. Pach and Company warranty does not guarantee any product, new or repaired, to be free of operation error orservice interruption in any way during t

Page 5

CHAPTER 2. INSTCHAPTER 2. INSTALLAALLATIONTIONA proper installation of the AeGIS system is very essential. You MUST follow the installation-wiring ste

Page 6 - LIMITATIONS OF LIABILITY

Pach and Company Page 5AeGIS 4000 Chapter 2. InstallationFigure 2.2 AeGIS 4000 Two Systems, Two Entrances Apllication Wiring DiagramSystem #1, Entran

Page 7 - CHAPTER 1. GETTING ST

The wiring diagram in figure 2.1 is numbered. Follow the step below according to the wiring number shown in figure2.1.Step 1 CO1, CO2, TN1, and TN2 to

Page 8 - 1.6 Unpacking the System

Connect to Normally Closed (N.C) and COM if normally closed door strike is used. Door is closed if the strike is energized and open if not energized•

Page 9 - 1.7 Warranty

CHAPTER 3. PROGRAMMINGCHAPTER 3. PROGRAMMINGThe AeGIS 4000 can be programmed Local (using built-in keypad), Premise Phone or Remote Phone. Premise pho

Page 10

01-20INDIVIDUALACCESS CODETO ACCESSRELAY 1(DOOR 1)21-40INDIVIDUALACCESS CODETO ACCESSRELAY 2(DOOR 2)41-50INDIVIDUALACCESS CODETO ACCESSBOTH RELAY 1AND

Page 11

51 RELAY 1 (DOOR 1) OPENINTERVAL(01-90 seconds)Step 1 Entering The ProgrammingMode: Press 0 and # simultaneouslythen release. If you are in theprogram

Page 13 - Pach and Company Page 4

Pach and Company Page 11AeGIS 4000 Chapter 3. Programming52RELAY 2(DOOR 2) OPENINTERVAL(01-90 seconds)60-62 DELETEINDIVIDUALACCESS CODE 60:INDEXNUMBE

Page 14 - System #2, Entrance #2

Pach and Company Page 12AeGIS 4000 Chapter 3. Programming70DIRECT CALLFORWARDINGIS USED IF A DEDICATEDPHONE LINE ISUSED OR IFYOU WANT TOFORWARD THECA

Page 15 - Pach and Company Page 6

71-72AUTOMATIC ORMANUAL CALLFORWARDINGSEE FUNCTIONCODES 87, 88AND 89 IF YOUWANT TO SETTHE SYSTEMFORAUTOMATICCALLFORWARDING.SEE ENABLEMANUAL CALLFORWA

Page 16 - Pach and Company Page 7

76DELETE ALLCALLFORWARDINGPHONENUMBER ONFUNCTIONCODE 70, 71 and7287ENABLE ORDISABLEAUTOMATICCALLFORWARDING“One Short Beep” and select anotherFunction

Page 17 - CHAPTER 3. PROGRAMMING

88SELECTAUTOMATICCALLFORWARDINGFUNCTIONNUMBER89SET AUTOMATICCALLFORWARDINGTIME ORHANG-UP TIMETHE SYSTEMWILL HANG-UPACCORDING TOTHE TIMESELECTED ONFUNC

Page 18

Pach and Company Page 16AeGIS 4000 Chapter 3. Programming90MANUALUNLOCK ORLOCK RELAY 1(DOOR 1)91MANUALUNLOCK ORLOCK RELAY 2(DOOR 2)Step 4 Select the

Page 19 - (DOOR 1) OPEN

92TALK TIME(10-90 seconds)THE SYSTEMWILL BEDISCONNECTEDACCORDING TOTHE TALK TIMEPROGRAMMED.93LOCK OUTCOUNT(03-09)THE SYSTEMWILL BEDISABLED FOR50 SECON

Page 20

94AUXILIARYMODEAUXILIARYINPUT CAN BEUSED FORTIMER, DOORRELEASESWITCH, ETC.95ALARM MODETHE SYSTEMWILL BEEP ORCALL THEREMOTE PHONEIF INVALIDACCESS CODES

Page 21

96SYSTEMANSWER MODEENABLE ORDISABLE THEAUTO ANSWERMODE. IFDISABLE THESYSTEM WILLNOT ANSWERAN INCOMINGCALL FROM THEOUTSIDE LINE.97DO NOTDISTURB MODEDIS

Page 22

98SELECT INITIATINGPREMISE CALLKEY## or **99SET MEMORYTO FACTORYDEFAULTERASE THEMEMORY ANDRESET THESYSTEM TOFACTORYDEFAULT, THEMASTER CODEIS ALSO RESE

Page 24

CHAPTER 4. OPERACHAPTER 4. OPERATIONSTIONSIt is important for you to understand the system’s operations completely for the most ease of operations. Yo

Page 25

ENABLE AND DISABLE CALLFORWARDING.ACTIVATE AUTOMATIC CALLFORWARDINGUNLOCK CYCLE, UNLOCKHOLD AND LOCK RELAY 1(DOOR 1) AND RELAY 2 (DOOR2).Pach and Comp

Page 26

HANG-UP AEGIS CALLS FROMPREMISE OR REMOTELOCATIONCALL AND TALK TO THE AEGISFROM PREMISE OR REMOTELOCATIONStep 5 Enter another Function Code to program

Page 27

ALARM NOTIFICATIONAUXILIARY INPUT PIN (AUI)DO NOT DISTURBHOW TO USE SPEED DIALING Step 2 Dial the AeGIS phone number and you will hear “One Short Beep

Page 28

CHAPTER 5. TROUBLECHAPTER 5. TROUBLESHOOTINGSHOOTINGGUIDESGUIDESNO TONE WHEN KEYS AREPRESSED.VISITOR CAN’T HEAR THETENANT VOICE BUT TENANTCAN HEAR THE

Page 29

THE SYSTEM DISCONNECTSWHEN THE TENANTS ANSWERTHE CALL.HOME PHONE(S) HAS NO DIALTONE.RADIO STATION PROBLEM.STATIC PROBLEM.Sound keeps breaking out. NUM

Page 30 - CHAPTER 4. OPERA

CHAPTER 6. PCHAPTER 6. PARAMETERS WORKSHEETARAMETERS WORKSHEETYou must keep accurate system’s parameters and database records at all time for future r

Page 31 - DESCRIPTION ACTION

1. To place a call from the AeGIS 4000: Press #.2. To grant access to a visitor: Press 9 (door 1) or Press 8 (door 2).3. To use a personal access code

Page 32

TABLE OF CONTENTSLIMITATION OF LIABILITYCHAPTER 1. GETTING STARTED ...

Page 33

CHAPTER 5. TROUBLE SHOOTING GUIDES ... 25Aud

Page 34 - COMMUNICATION PROBLEMS

LIMITATIONS OF LIABILITYThis manual is subject to change without notice.Pach and Company is not liable for any errors that might occur from use of thi

Page 35 - GATE PROBLEMS

CHAPTER 1. GETTING STCHAPTER 1. GETTING STARTEDARTED1.1 IntroductionPach & Company thanks and congratulates you on the purchase of your AeGIS 4000

Page 36 - ARAMETERS WORKSHEET

• Talk Time• Personal Access Code• Call Forwarding automatic or manualTechnical Specifications:Power Input: 12VAC 20VA UL Listed Transformer (Pach sup

Page 37 - SYSTEM OPERATION

1.7 WarrantyPach and Company new products are warranted to be free of defects in material or workmanship for a period of twoyears, (24 months), from t

Commentaires sur ces manuels

Pas de commentaire