Missing Parts, contact Pach and Company 1-888-678-7224
Defective system under manufacturer warranty,
call 1-888-678-7224 for advance replacement
24 Months warranty
for complete system
6 Months warranty
for Printed Circuit Board
Manuals are available online at www.
p
ach-co.com
Exit program, cancel call 23 Lock-out Count
Save program 24 Alarm
0= disable
1= local beep for 60
seconds
2= disable system for 60
seconds with no beep
3= call directory (0-9)
00 Change master code (0000 is
default)
25 Keypad beep
0= disable (default)
1=enable
01 Add new forwarding tenant’s
directory
26 Door beep
0= disable
1= enable (default)
02 Edit existing tenant’s directory 27 Talk time (060-240
second). Default=60
second
03 Delete existing tenant’s
directory
28 Unlock relay1 time
(12-99 second). Default=
12 second
04 Clear all forwarding tenant’s
directory
29 Unlock relay2 time
(12-99 second). Default=
12 second
05 Enable/Disable Call 33 Temporary code
06 New access code 34 Special code
07 Delete access code 35 Temporary card
08 Clear all access code 36 Special card
09 Access code digit (4-8 digit).
Default is 4-digit
38 System acknowledge
(0-9). Default= 3
10 Add new card 39 Remote access
0= disable
1=enable (default)
11 Delete card 40 DTMF relay 1 (0-9).
Default=9
12 Clear all card 41 DTMF relay 2 (0-9).
Default=8
13 Set time 42 Relay 2 Mode
1= door control (default)
2= relay 2 trigger
simultaneously as relay 1
3= enable if function code
24 is enable
4= turn relay 2 on and off
On=7, Off=6
14 Set date 43 DND: do not disturb time
zone (0-9)
15 Initializing event recording 44 Disable Time zone relay
1, 2 or both
16 AUS= auto unlock schedule
(0-9 schedule)
45 Relay 1 and 2 unlock
timer
17 TMZ= time zone. 20 TMZ, 00-
20.
46 Firmware version
18 HLD= holiday zone. 20 HLD,
1-20
48 PBX enable. Default=
disable
19 Directory digit (2-4 digit).
Default is 2-digit
49 Edit Access code
20 AUXIN1
0= disable (default)
1= enable control by relay 1
open interval
2= relay 1 control by AUXIN1
50 Erase the memory to
factory default
21 AUXIN2
0= disable (default)
1= enable control by relay 2
open interval
2= relay 2 control by AUXIN2
51 Welcome screen
22 Do not disturb
0= disable (default), 1= enable
Log on to programming: Press
and simultaneously then release,
the welcome message will stop
scrolling (repeat if screen still scrolls)
enter 4-digit “MASTER CODE” (0000
is default), the screen will show:
Select the “Function Code” from the
table
OPERATION
Opening the door remotely
press (relay 1) or (relay 2)
Opening the door with the access code
press (display
screen will stop scrolling) then press a valid 4-digit access code.
Extending talk time
tenant must press from the phone after
the time out warning beep.
Calling into the system
:
1. Enable function code 39 and function code 38 must be set 1-9
2. Call the system phone number, hear one beep if the system
answering the call.
3. Press then 4-digit master code, hear one short beep
4. Press to establish two way communication
5
.Pr
ess
o
r t
o
r
e
l
ease
th
e
doo
r.
OPERATION
Two ways call from the system
1. Press to scroll name from A-Z or to scroll name from Z-A
then press to call name selected.
2. Press wait for dial tone then press the directory number
QC1IP and QC2IP DEFAULT IP
IP: 192.168.1.230
SUBNET: 255.255.255.0
GATEWAY: 192.168.1.1
DNS: 192.168.1.1
USERNAME: Administrator
PASSWORD: 8888
WARNING: DO NOT USE ON BOARD
12VDC and GND TO POWER A DOOR
STRIKE OR MAGNETIC LOCK
SEPARATE POWER MUST BE USED TO
POWER A DOOR STRIKE OR MAGNETIC
LOCK.
Vue de la page 0
1 2

Résumé du contenu

Page 1 - WARNING: DO NOT USE ON BOARD

 Missing Parts, contact Pach and Company 1-888-678-7224  Defective s

Page 2 - QUANTUM QC1IP

QUANTUM QC1IP QUANTUM QC SERIES Technical Support is available Monday-Friday 7:00 am-4:

Commentaires sur ces manuels

Pas de commentaire